RO system sizer

Enter the water you need and the water you have. Get feed and concentrate flows, permeate quality, osmotic pressure and the number of membrane elements and pressure vessels, arranged in stages with hydraulic checks.

Your inputs

Water source

gal/day

173.6 gpm · 946 m³/day

mg/L

Total dissolved solids of the raw water.

75%

Share of the feed that becomes product water.

99.5%
16.0gfd

Typical: seawater 7–10, wastewater 8–12, surface water 10–14, well water 14–18 gfd.

Results

Membrane elements required

46in 8 pressure vessels · Array 5 : 3

48 installed at 13.0 gfd average operating flux

RO MEMBRANESFEED333,333 gpdPERMEATE · 75%250,000 gpdCONCENTRATE · 25%83,333 gpd
Feed flow
231.5gpm
1,262 m³/day
Concentrate flow
57.9gpm
315 m³/day
Concentration factor
3.97×
Permeate TDS
18.5mg/L
Concentrate TDS
7,945mg/L
Osmotic pressure
91psi
concentrate · feed 23 psi
Feed per first-stage vessel
46.3gpm
maximum 75 gpm
Concentrate per last-stage vessel
19.3gpm
minimum 16 gpm

Vessel array

Stage 1 · 5 vessels

Stage 2 · 3 vessels

Check this concentrate for scaling
How this is calculated

Flows. Feed = Permeate ÷ Recovery and Concentrate = Feed − Permeate.

Salt balance. Salts stay on the feed side, so the water gets saltier as it moves down the vessel. The average feed-side concentration is Feed TDS × ln(1 ÷ (1 − R)) ÷ R. Permeate TDS is that average times salt passage (1 − rejection), and concentrate TDS follows from the mass balance (Feed TDS − R × Permeate TDS) ÷ (1 − R).

Membranes. Membranes lose output as they age, so the design uses 85% of the clean flux: Elements = Permeate (gpd) ÷ (Flux (gfd) × 0.85 × Element area (ft²)), rounded up, then grouped into pressure vessels.

Stages. One vessel can only recover about 50–55%, so higher recoveries are split into stages with fewer vessels toward the end. Up to 55% recovery is 1 stage. From 56% to 80% it is 2 stages, where stage 2 holds the smaller of 40% of the vessels and concentrate gpm ÷ 16 (rounded down, at least 1). Above 80% it is 3 stages, at about 50%, 30% and 20% of the vessels.

Hydraulic checks. Concentrate per last-stage vessel must stay above 16 gpm for 8-inch elements (4 gpm for 4-inch), or the membranes foul and scale. Feed per first-stage vessel must stay below 75 gpm for 8-inch elements (16 gpm for 4-inch).

Assumptions

  • Single-pass system with one average flux across all elements.
  • Element count includes a 15% allowance for flux decline over the membrane life.
  • Osmotic pressure uses about 0.0115 psi per mg/L, which fits sodium chloride waters.
  • Temperature and feed pressure are not modelled.
  • A preliminary sizing only. AWP runs a full membrane projection for every quote.